IBL/25-OH-Vitamin D ELISA/RE53041/
IBL/25-OH-Vitamin D ELISA/RE53041/
商品编号: RE53041
品牌: TECAN
市场价: ¥7520.00
美元价: 4512.00
产地: 美国(厂家直采)
公司:
产品分类: 夹心法ELISA
公司分类: Sandwich_method_ELISA
联系Q Q: 3392242852
电话号码: 4000-520-616
电子邮箱: info@ebiomall.com
商品介绍
Kitsize12x8
MethodELISA
Incubationtime1x90min.,1x30min.,1x15min.
Standardrange0-130ng/mL
Specimen/Volumes25µLserum
Substrate/isotopeTMB450nm
RegulatoryStatus:EU:CE
Detailsfor: 25-OH-VitaminDELISA

TheroleofvitaminDindevelopmentofbone-relateddiseasesintheboneandmineralmetabolismhadbeendiscoveredsincemanyyears.

Clinicalrelevance

Theaccurateassessmentofaperson’svitaminDstatusreliesonthemeasurementof25-OH-vitaminDtotal(25-OH-vitaminD2+25-OH-vitaminD3)levels.ThereforeourassayhasbeendevelopedtodetectbothD2andD3variants.TheroleofvitaminDinregulatingthecalcium-phosphorusbalancefornormalbonemineralizationiswellknownsincemanyyears.Thusthedeterminationof25-OH-vitaminDhaslongbeenusedfordiagnosisandmonitoringtherapyofrickets,renalosteodystrophy,osteomalaciaandpostmenopausalosteoporosis.

Morerecentstudiesindicatethatinsufficient(seetablebelow)vitaminDlevelsarecorrelatedwithincreasedriskofdevelopingotherdiseases,suchascancer,hypertension,diabetes,cardiovasculardiseasesandmanymore.

Suggestedreferencevalues
Deficiency<10ng/mL
Insufficiency10-30ng/mL
Sufficiency30-100ng/mL
Toxicity>100ng/mL

CorrelationtoLC-MS/MS

TheIBL-International25-OH-VitaminDELISAiscorrelatedagainsttheLC-MS/MSreferencemethod.

Thecorrelationwasperformedon135serumsamplescomparingtheIBL-International25-OH-VitaminDELISAtotheLC-MS/MS.Theregressionanalysisshowedaslopeof1.042,aninterceptof-3.731ng/mLwithacorrelationofR=0.92.

Graph1:CorrelationtoLC-MS/MS

Automation

TheIBLInternational25-OH-VitaminDELISAhasbeendevelopedtobeadaptabletoopenELISAprocessors.Anin-housecorrelationhasbeenperformedcomparingthemanualwork-upofthe25-OH-VitaminDELISAandtheautomatedwork-upofthe25-OH-VitaminDELISAontheTECANFreedomEVOlyzer®.Theregressionanalysisshowedaslopeof0.9737,aninterceptof-0.269ng/mLwithacorrelationofR=0.99.

Graph2:CorrelationofautomatedEVOlyzer®testingtomanualwork-up

AdvantagesofourELISA

  • ExcellentcorrelationtotheLC-MS/MSreferencemethod
    RE53041=1.042xLCMS-3.731,R=0.92
  • Directassaywithoutextraction
  • Ready-to-usereagents
  • EasilyadaptableonopenELISAplatforms
ForconcretedatapleaseconsulttheInstructionforUseinthedownloadboxontherightside.
品牌介绍
IBL我们的愿景是通过Tecan技术,产品和支持,为世界各地的每个实验室提供支持。我们旨在通过无与伦比的专业知识,产品和客户支持来塑造生命科学和临床诊断自动化工作流程的未来。